Routine maintenance of electromagnetic flowmeter

Issuing time:2018-01-30 09:28

Routine maintenance of electromagnetic flowmeter

Hello, everyone, today small make up for you is about the electromagnetic flow meter routine maintenance method.

Measurement of electrode contact resistance measurement of liquid contact resistance of electrode spoon can indirectly estimate the general condition of electrode and lining surface without removing the flow sensor from the pipe, which is helpful to analyze the cause of failure.

The polarization voltage between the electrode and the liquid will be helpful to determine whether the zero point instability or output sloshing fault is caused by the contamination or coverage of the electrode. The polarization voltage between the two electrodes and the ground can be measured respectively with the digital multimeter 2V dc (the electromagnetic flowmeter can be measured without power failure or without power failure). If the two measurements are nearly equal, the electrode is not contaminated or covered; otherwise, the electrode is contaminated or covered. The polarization voltage depends on the "electrode potential" of the electrode material and the properties of the liquid. In fact, the contamination of two electrodes in operation cannot be completely symmetrical, so the voltage on the two electrodes forms an asymmetric common mode voltage. The asymmetric common mode voltage becomes the differential mode signal, causing the zero offset.

Measurement of signal cable interference signal cable interference by external electrostatic induction and electromagnetic induction will cause zero changes in the electromagnetic flowmeter. In order to determine whether the zero point change is affected by the signal cable interference potential, it is necessary to measure the general range of interference and the degree of influence on the electromagnetic flowmeter.

Four, determine whether there is a ground potential electromagnetic flow juice in the normal use of the process, such as the sensor near the electrical (force) machine state changes (such as leakage), the ground potential will change and cause zero change. Check for this effect by short-circuiting the earthing C terminal of the converter to the protective earthing G terminal, and judge whether there is a ground potential by the change of zero (or indicating value).

In order to narrow the search scope, it is necessary to reduce or eliminate the influence of stray current on the upstream of the flow sensor.

The above is about the electromagnetic flow meter routine maintenance method, I hope to help you.


Share to:
推薦閱讀
文章附圖

孔板流量計包含了三個部分:一是孔板;二是導壓管路;三是差壓變送器。其中,孔板屬于節流元件,主要作用是把介質轉換為差...

文章附圖

污水流量計可廣泛用于市政給供水、鋼鐵、石油、化工、電力、工業、水利、水政水資源等部門的液體的體積流量的測量,特別適...

文章附圖

近幾年隨著對流量計的研究和開發,流量儀表選型呈現從單一儀表向多元化儀表方向發展,隨著天然氣在一次能源中的比例逐年增...

文章附圖

隨著天然氣產業的大發展,天然氣流量計工作也獲得了越來越多的重視,我國已經在天然氣流量儀表的設計選型、使用、安裝、維...

Customer Cases

Customer Cases

Customer Cases

Perkins
Product name:
electromagnetic flowmeter Date of purchase: May 2015 Purchase quantity: 8 sets
Product name:
vortex street flowmeter
Date of purchase: July 2016
Purchase quantity: 5 sets
Wuxi Shenli
Buy product name:
differential pressure transmitter
Date of purchase: March 2017
Purchase quantity: 7 sets
Walter machinery
Purchase product name:
digital display table
Date of purchase: April 2018
Purchase quantity: 11 sets
Wanyuan environment
Wuxi oubai instrument technology co., ltd. has a number of excellent r & d team, and with jiangnan university, wuxi business school and other universities and enterprises cooperation. The company has a sound sales and after-sales service system and efficient marketing team; The product sales coverage keeps growing all the year round.
In the industry, it is one of the production and sales enterprises of flow meters with a complete range of products and a large scale, which produces good electromagnetic flowmeters, liquid flowmeters, gas flowmeters, etc.
The company focuses on user practice and product research and development, and has obtained a number of patents and research and development results, and has mature experience in the research and development, design, manufacturing and installation of flow meter equipment in various industries.
7 * 24-hour service system, one year guaranteed, so that you at any time product problems we can solve as soon as possible for you, to ensure the interests of customers;
Set up a group of professional teams, engaged in design, production, sales and installation services;
To the well-known large projects have done supporting, set up many classic cases;
index | electromagnetic flowmeter | vortex street flowmeter | open channel flowmeter | product center | case analysis | about our | news center | contact us
Address: 11-2-4, jinshan fourth branch road, beitang district, wuxi city, jiangsu province Hot line: 0510-89052999 0510-82358878 The true: 0510-89052999 Hand machine: 18661273788
Q Q: 630441747
Mail box: sales@wxobai.com
Mail editor: 214000
Technical support: le shi tong